Hill-Rom® synergy air elite low air loss mattress

Hill-Rom® synergy air elite low air loss mattress

This mattress allows caregivers to create customized safe skin programs for their patients. Synergy air elite powered mattress features comfort control that facilitates pressure redistribution to suit the individual needs and the low-air-loss capability helps keep your patient’s skin cool and dry. This therapeutic surface provides flexibility and comfort throughout the healing period by providing the option to choose alternating pressure therapy when your patient needs it.

Demonstration Videos

For privacy reasons YouTube needs your permission to be loaded.
For privacy reasons YouTube needs your permission to be loaded.

Guidelines, Specifications & User Manuals

User Information

Other Documents

Helpful Information

How to setup and use hill rom synergy air elite bed

Setting up and using the Hill-Rom Synergy Air Elite bed is essential for providing optimal patient care and comfort. Below is a step-by-step guide to help you through the process:

Setting Up the Hill-Rom Synergy Air Elite Bed

Supplies Needed

– Hill-Rom Synergy Air Elite bed

– Power source (plug)

– Patient positioning aids (if necessary)

– User manual for reference

Steps for Setup

  1. Preparation:

– Ensure the area around the bed is clear and accessible.

– Check that the bed is clean and free from any debris or items.

  1. Position the Bed:

– Move the bed to the desired location in the patient room.

– Ensure that the bed is positioned on a flat surface.

  1. Connect to Power:

– Plug the bed into a power source. Ensure that the power cord is securely connected and not obstructing any pathways.

– Verify that the electrical outlet is functioning properly.

  1. Adjust the Bed Height:

– Use the bed’s control panel or hand control to adjust the height of the bed to a comfortable level for patient transfer and care.

  1. Set Up the Mattress:

– Ensure that the mattress is properly installed on the bed frame.

– Check that the mattress is inflated and functioning correctly. The Synergy Air Elite mattress should automatically adjust based on the patient’s weight and position.

  1. Check Pressure Settings:

– Access the control panel to adjust the pressure settings according to the patient’s needs. The bed may have different modes for pressure relief and comfort.

  1. Secure Side Rails:

– If applicable, ensure that the side rails are raised for patient safety, especially if the patient is at risk of falling.

Using the Hill-Rom Synergy Air Elite Bed

Daily Use

  1. Patient Positioning:

– Use the control panel to adjust the bed to the desired position for patient care (e.g., sitting up, reclining).

– Utilize positioning aids if needed to ensure patient comfort and safety.

  1. Monitor Pressure Relief:

– Regularly check the pressure settings to ensure they are appropriate for the patient’s condition. Adjust as necessary to prevent pressure ulcers.

  1. Bed Alarm Settings:

– Familiarize yourself with the alarm settings on the bed. Ensure that alarms are enabled to alert staff if the patient attempts to get out of bed or if there are any issues with the mattress.

  1. Daily Maintenance:

– Inspect the bed daily for any signs of wear or malfunction.

– Ensure that the mattress cover is clean and free from damage.

Changing Patient Position

  1. Adjust the Bed:

– Use the control panel to raise or lower the head and foot sections of the bed as needed for patient comfort.

  1. Reposition the Patient:

– With the bed in the appropriate position, assist the patient in changing positions, using proper body mechanics to avoid injury.

  1. Reassess Pressure Settings:

– After repositioning, reassess the pressure settings to ensure continued comfort and pressure relief.

Additional Tips

– Training: Ensure that all staff members who will be using the bed are trained in its operation.

– Patient Education: Educate patients and caregivers on how to use the controls safely and effectively.

– Documentation: Document any changes in patient condition, bed settings, and any issues encountered during use.

By following these steps, you can effectively set up and use the Hill-Rom Synergy Air Elite bed, promoting patient comfort and safety. If you encounter any issues or have questions, consult the user manual or contact a healthcare professional for assistance.

Synergy® Air Elite Low Air Loss Therapy features:

  • Low air loss therapy for moisture control helps keep the skin cool and promotes a dry healing environment
  • Alternating pressure therapy provides pressure redistribution for the prevention and treatment of pressure ulcers
  • Individual air cushions have adjustable pressure to suit individual patient comfort needs
  • Waterproof and vapor permeable ticking
  • Max inflate provides uniform firmness to accommodate caregiver procedures and safe transfers
  • 2.5” foam base provides support in the event of a power failure
Standard Length 80″ or 84″
Standard Width 36″
Standard Height 10″
Therapeutic Patient Weight Limit 600 lb
Weight 33 lb
Flammability 16CFR1633, 16CFR1632, and Cal 129 only
Bariatric Version
Standard Length 85″
Width 39″, 48″
Height 10″
Therapeutic Patient Weight Limit 1,000 lb
Weight 40 lb
Flammability 16CFR1633, 16CFR1632, and Cal 129 only
Air Supply
Length 16.5″
Width 6.7″
Height 10.6″
Weight 13.2 lb